Products Products
Product Name:

Technical Parameters Uncertainty of flow measurement system

Date: 2016-03-17

pressurized pipe or square culvert        ± 0.5% (4 or 8 channels)

 Electronic part of the technical parameters

Work Environment            Air temperature  ~ 50 

Relative humidity <90% (non-condensing) 

 Storage Environment          -20℃~+70

Relative humidity <95% (non-condensing) 

 Power supply                AC220V±20%,50H

Power                     80W 

 Output                     Color liquid crystal display (color TFT) 

Printer output 

RS-232/485 serial communication port 

4 ~ 20mA analog output port (optional) 

Relay output (optional) 

Size                      344×260×152mm

Weight                    9.5Kg

work                      A long line 

Operating ambient temperature  -5℃~50

 Storage temperature          -20℃~+70

Relative humidity <90% (non-condensing) 

 Power supply               AC220V±20%,50HZ

 Protection class             IP65

 Size                      300×400×120mm

 Weight                    6.5Kg

Power                    10W

loudest road capability        10

 Transducer acoustic path angle 65°or45°

 Operating temperature transducer           0℃~+40

 Storage temperature transducer            -18℃~+65

 Working Pressure transducer             H9110 高压型外插式换能器10.0 MPa

H9110 Extrapolation transducer 5.0 MPa

                                            H9210 Built-in high pressure transducer 6.0 Mpa

H9210 Built-in transducer 3.0 Mpa

 Emission voltage transducer               29V70V167V400V Optional

 Transducer frequency                    1MHz500KHz200KHz Optional

 Transducer Size                        H9110 Extrapolation transducer Ø25×300

                                        H9210 Built-in transducer Ø45×140

 Transducer weight                       H9110 Extrapolation transducer 1Kg

                                        H9111 Extrapolation transducer 1Kg

                                        Z9110 Extrapolation transducer seat 6Kg

H9210 Built-in transducer 0.2Kg

Z9210 Built-in transducer mount 1Kg

 Test water quality conditions               Water temperature        040

Water insoluble content of <2% (by volume) 

measuring pipe diameter range 0.515m

measuring channel width 1100m

 

 

 

 

 

 