Products Products
Product List
一、Outline:                                                Oil mixing with water signal is used to monitor hydropower, thermal power plants and large-scale systems pumping oil mixing with water or water quantity. When the fuel tank, mixing with water or water in oil pipeline that is a warning signal to alert staff on duty promptl...
一、 the purpose and principleThe signal level meter for water, fire power plants and other industrial sectors of water, oil, medium level of monitoring, control, limit alarm, etc.The signal Simple structure, mainly magnetic and magnetic water float float oil packed in plexiglass tube, (WXJ type float insert liquid tank), the float level with the lift and upper and lower action, you can directly observe the test high and low level. In the ...
一、 use:One signaling device signaling device shaft peristaltic hydropower units are designed for condition monitoring. When the unit is shut down, when as a result of poor sealing vanes or other reasons, leaking is excessive, often leads to unit shaft motility, which each part of the unit pad thrust bearing bush in particular caused a very negative impact, damage to the unit performance and service life, therefore, at the unit shutdown, moni...
1、Outline:1)Device is designed for CT, PT following tests: the excitation characteristics test, ratio test, phase and polarity test;2)CT worse than the current variety of time and various load, the angle difference measurement3)CT secondary winding resistance measurement4)CT secondary circuit load measurement5)CT Transient Measurement and Analysis6)Checking measuring various types of CT, PT, including the protection of CT, metering CT, TP level transient CT, excitation saturation ...
1、Outline      WXYJ-100 wireless pressure drop and load tester wirelessly auto-complete phase three-wire or four-wire three-phase voltage transformer secondary voltage drop measurement is not required in the normal way to the distal end of the instrument to test the laying of a long test line voltage, thus avoiding unnecessary short circuit caused because the line is too long, and this is the voltage transformer should be avoided; but s...
1、Outline      SDPT-H high school low voltage transformer tester is my company in the field in order to reduce electromagnetic voltage transformer test workload situations designed to field test equipment. The instrument has a low voltage situation check out the actual error voltage transformer in high voltage conditions. Can cover 6kV / 100V, 6kV / √3 / 100V / √3, 10kV / 100V, 10kV / √3 / 100V / √3, 35kV / 100V,...
1) Measuring range:20% to 200% of rated primary voltage valuesRated secondary voltage: 100 / √3V, 100V2) Accuracy level: 33) The rated capacity:Rated voltage 100 / √3V, the rated capacity (unit: VA) is: O, 0.07; 1.25; 2.5; 3.75; 5; 6.25; 7.5; 10; 12.5; 15; 20. Power factor: COSΦ = 0.8,1.0Rated voltage 100V, the rated capacity (unit: VA) as follows: 0, 0.2; 1.25; 2.5; 3.75; 5; 6.25; 7.5; 10; 12.5; 15; 20. Power factor: COSΦ = 0...
Performance      qOverall structure Definition and electrical installation example Selection Guide
Standard voltage transformer other technical indicators in line with JB / T5473-1991 "Instrument voltage transformers", JJG314-94 "measuring voltage transformer test procedures" of the relevant provisions1) measuring range: 20 to 120% of rated2) Accuracy: 0.053) primary voltage rating: 500kV /, 220 kV / kV, 110 / kV, 350 / kV10 / kV4) secondary voltage rating: 0.1 / kV, 0.1kV5) Rated capacity: 0.25VA6) rated power factor: 0.8,1.07) insulation in&...
Total28ArticlePage3/4HomeLast page1234Next pageEnd